Analytik Jena UVP CL-3000 UV crosslinker


The Analytik Jena CL-3000 UV Crosslinker is the ideal UV crosslinker for scientific laboratories, hospitals and microbiology labs. It is designed to measure and control the ultraviolet (UV) radiation within the exposure chamber and a unique UV sensor continually measures the UV energy and automatically adjusts to variations in UV intensity that occurs as the UV tubes age. This same UV sensor feedback measurement system allows you to set UV sample exposure, which automatically deactivates the UV sources when the set UV energy dose has been achieved.

  • Crosslinking of DNA and RNA to nylon or nitrocellulose membranes

  • Microprocessor control provides precise UV dose control

  • Irradiation can be defined as energy (Joules/cm²) or time (seconds

Analytik Jena CL-3000 UV Crosslinker

Product Details

  • Preset programs for nucleic acid immobilization at 120 mJoule/cm2
  • Safety interlock door with UV protection glass

Shortwave UV (UVC) as a Disinfectant

Ultraviolet light is considered an ancillary disinfectant to chemical disinfectants in the healthcare environment. The high-precision CL-3000 crosslinker is capable of producing a cumulative dosage of 1 J/cm2 , this is considered well beyond the requirement needed for disinfection. The CL-3000 provides near uniform UVC light with a ~10% coefficient of variation and less than 2 mJ/cm2 difference between the highest and lowest reading. Most importantly, the CL-3000 has real-time monitoring of UVC dosage to assure reproducible dosing irrespective of space and time.

Immobilization of Nucleic Acids to Membranes

The UVP Crosslinker is a microprocessor controlled UV irradiation system dedicated to nucleic acid linking to membranes for Southern, Northern, Dot and Slot Blot applications. It can also be used for UV disinfection and for elimination of PCR contaminations.

Microprocessor Controlled Reproducibility
The programmable microprocessor constantly monitors the UV light emission. Irradiation stops exactly when the programmed energy is achieved. Thus, the effect of decreasing UV intensity due to bulb aging is compensated for.

Durability
The UVP Crosslinker combines the latest UV technology with high quality manufacturing: aluminum UV exposure chamber, protective quartz disk on the UV sensor cell, and a highly resistant and easy-to-clean keypad and housing.

Ease of use
The large display provides a series of predefined methods, making the UVP Crosslinker an easy to use yet powerful instrument for immobilization of nucleic acids to membranes. The programmed data are shown on the LED display.

    Applications

    • Shortwave 254nm UV:
      UV crosslinking membranes
    • Longwave 365nm UV:
      UV curing, non-destructive testing
    • Midrange 302nm UV:
      Photochemical reactions, UV crosslinking

     

    Do you have questions? Contact customer support by phone or online. One of our product specialists will be happy to help you.



    Documents:

    What applications can the CL-3000 be used for? The UVP Crosslinker offers researchers an instrument to quickly, safely and efficiently expose samples to a controlled amount of ultraviolet radiation. The 3 different versions, each with a different UV wavelength (254nm, 302nm, 365nm), provides the following for exposed samples:

    • Crosslinking of DNA or RNA to nitrocellulose, nylon or reinforcednitrocellulose
    • PCR sample contamination control
    • Photo nicking ofDNA
    • Testing RecA function
    • Rapid site mapping
    • UV curing

    What is the maximum exposure setting for the CL-3000? 9999.9 mJ/cm2

    What is the maximum time exposure for the CL-3000? 
    9999:59

    Are there operational presets available with the UVP CL-3000? Yes, two operational crosslinker settings are available.

    • Preset UV Energy Exposure: provides a measured dose of UV exposure to the sample.
    • Preset UV Time Exposure: measures exposure time without regard to exposure intensity; therefore, when the unit is used in the Preset UV Time Exposure mode, there is no sensor involvement and thus there is no stated intensity value being delivered to the sample.

    Can the user define settings for the CL-3000? Yes, users can create a UV energy setting or a UV time exposure setting.

    Can you change the wavelength of the CL-3000? The  CL-3000 is purchased with shortwave, long wave or midrange tubes. However, if user requirements and applications change, the UVP Crosslinker provide you with the unique ability to change the ultraviolet wavelength and recalibrate the UV sensor and microprocessor to the new UV wavelength. This is accomplished by purchasing six tubes of the new UV wavelength and the proper Analytik Jena calibration sensor. Speak to a Transilluminators.com expert to help with this.

    Wavelengths  254nm (CL-3000), 302nm (CL-3000M), 365nm (CL-3000L)
    Bulbs 6 x 8 Watt
    Energy 0000.1 - 9999.9 mJ/cm² (0 - 10 J/cm²)
    Time 000:01 - 999:59 (>300 J/cm²)
    Temperature 15⁰C - 35⁰C
    Humidity 70% Non-Condensing
    Altitude up to 3,000M (9,842 ft)
    Sound Level ≤ 50 dba
    Housing Surface Temp ≤ 30⁰C
    Startup Time < 1 sec
    External Dim (L x W x H) 41 cm x 40 cm x 26.5 cm
    Internal Dim (L x W x H) 35 cm x 27 cm x 16 cm
    Weight 6.8 Kg: 15 lb
    Operating Power 100 - 115VAC & 230VAC 50/60Hz
    Certifications CE, RoHS (CSA In Process

    Ordering information

    • Catalog numbers: NEB-849-95-0615-01 (254nm shortwave), NEB-849-95-0615-05 (365nm longwave), NEB-849-95-0615-03 (302nm midwave)
    • Country of origin: USA
    • Ships from: CA
    • Warranty: One year
    • Shipping charge: $75.00
    • Typically ships within 10 days upon receipt of an order

    Contact Us

    Customer Reviews

    Based on 1 review
    100%
    (1)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    M
    Matt Fleming
    A great UV crosslinker

    Crosslinking takes a lot less time than using the one that we had before. The customer service was great too. They always kept us informed of the status of our order.

    Recently viewed