Benchmark Scientific UV Clave Ultraviolet Chamber
BLACK FRIDAY SPECIAL OFFER. Purchase the UV Clave by December 6, 2024 and receive a FREE myFuge Mini Centrifuge with 1.5/2mL tube rotor, 0.2mL strip tube rotor and 0.5mL tube adapters. A $376.00 value. Offer will be automatically applied when the UV Clave is purchased.
Short-wave UV light is an effective method for the disinfection of surface DNA, RNA and microorganisms. With the UVClave chamber, highly focused UV irradiation is used to disinfect tools, vessels and other research items, eliminating up to 99% of surface contamination.
Unlike most UV chambers, the UV Clave includes powerful UV-C bulbs on both the top and bottom of the chamber. When combined with our proprietary shelf that allows for >90% of UV-C light transmission and highly reflective chamber walls, the result is true 360° exposure with no blind spots.
Exposure time is adjustable. An optional heating cycle can be added to assist in drying items that may have been washed or chemically disinfected prior to insertion.
To protect users, the integrated auto shut-off prevents illumination when the door is open. Optional indicators are available to test for proper exposure levels.
Features of the UV Clave
- Improves quality of PCR research by reducing potential contaminants
- Multiple lamps and reflective chamber walls provide true 360° irradiation;
- Proprietary UVC transparent shelf, eliminates potential for missed coverage (blind spots)
- Inactivates DNA, RNA, viruses & bacteria on PCR vessels
- Adjustable cycle time
Frequently Asked Questions (FAQs)
Is the UV Clave heating adjustable? No, the heating temperature is 55 C. The heating timer can be set between 30 min. and 120 min. and set at 30 min. increments.
How many bulbs are in the UV Clave? There are 6 UV bulbs in the UV Clave. They are 254nm bulbs, 4W.What is the UV dosage? 600mJ/cm2 (20 min cycle)What is the UV intensity? +500µW/cm² (center of chamber)
Specifications
UV Bulbs: |
6 x 4W |
|
UV Wavelength: |
254nm |
|
UV Intensity: |
+500µW/cm² (center of chamber) |
|
UV Dosage: |
600mJ/cm2 (20 min cycle) |
|
UV Timer: |
5-20 min. (5 min. increments) |
|
Heater Timer: |
30 -120 min. (30 min. increments) |
|
Heater Temp.: |
55°C |
|
Internal Dims.: |
8.5x10.1x12.2 in / 21.6x25.6x31.8 cm |
|
External Dims.: |
11.5x10.5x15.7 in / 29.2x26.7x40 cm |
|
Max. Height: |
30 cm |
|
Shelf Dims.: |
10 x 8 in / 25.4 x 20.3 cm |
|
Shelf Material: |
2 Stainless steel wire / 1 UV-C transparent |
|
Weight: |
11lbs. (5kg) |
|
Electrical: |
120V 60HZ or 230V 50HZ - 110W |
Documents
UV Clave brochure: here